Résumé du contenu

Page 1 - User’s Guide

DP26-RTDDifferential TemperatureMeter with RTDomega.com e-mail: [email protected] latest product manualsomegamanual.infoUSAMADE INUser’s GuideShop on

Page 2 - Servicing Europe:

2SECTION 1.2 SAFETY CONSIDERATIONSThis device is marked with the international caution symbol. It is important to read this manual before installing

Page 3 - Optional Procedures:

3SECTION 2. ABOUT THE METER2.1 DESCRIPTIONThe Differential RTD meter is a value packed indicator/controller. Four full digitsaccurately display your

Page 4

42.3 AVAILABLE ACCESSORIESTable 2.1 Accessories and Add-onsAdd-On OptionsFS Special Calibration/ConfigurationSPC4 NEMA-4 Splash Proof CoverSPC18 NEMA-

Page 5 - NOTES, WARNINGS and CAUTIONS

52.4 FRONT OF THE METERFigure 5-1 shows the location of each part of the front of the meter. Figure 2-1 Front PanelDigital LED Display: -1.9.9.9.

Page 6 - Table of Contents

62.4 FRONT OF THE METER (Continued)METER BUTTONSSETPTS Button In the run mode, press this button to sequentially recall the previous setpoint setting

Page 7

72.4 FRONT OF THE METER (Continued)MENU ButtonIn the run mode, press the MENU button to terminate the current measuring processand enter you into the

Page 8 - List of Tables

2.5 FRONT PANEL LOCKOUT2.5.1 PUSH BUTTON LOCKOUTTo lock the RESET, MENU and SETPTS buttons, verify that the S3-A jumper isinstalled and the S3-E jumpe

Page 9 - SECTION 1. INTRODUCTION

92.6 BACK OF THE METERFigure 2-2 shows the connector label mounted at the top of the meter housing. Table2-2 gives a brief description of each connec

Page 10

102.6 BACK OF THE METER (Continued)Table 2-2 Connector DescriptionConnector DescriptionTB1-1 Setpoint 1: Normally open (N.O.1) connectionTB1-2 Setpoin

Page 11 - SECTION 2. ABOUT THE METER

2.7 DISASSEMBLYYou may need to open up the meter for one of the following reasons:• To check or change the 115 or 230 Vac power jumpers.• To install

Page 12 - Accessories

It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its pr

Page 13 - DEVT1/T2/SETPTS

SECTION 3. GETTING STARTEDCaution: The meter has no power-on switch, so it will be in operation assoon you apply power.If you power off/on the meter,

Page 14 - METER BUTTONS

3.2 MAIN BOARD POWER JUMPERS (Continued)Figure 3-2 shows the main board jumpers.Figure 3.2 Main Board Jumper PositionsFigure 3.3 Upper Option Board I

Page 15

3.2 MAIN BOARD POWER JUMPERS (Continued)S2 jumpers are for sensor break indications:* S2A jumper is not used* S2B jumper is for positive sensor break

Page 16 - 2.5 FRONT PANEL LOCKOUT

3.3 MOUNTING THE METERFigure 3-3 Meter - Exploded View1. Cut a hole in your panel, asshown in Figure 3-3. Forspecific dimensions refer toFigure 3-4.

Page 17 - (DIFFERENTIAL RTD)

3.4 CONNECTING SENSOR INPUTFigure 3-5 through 3-7 illustrate how to connect you power sensors.Figure 3-5 2-Wire RTD Input ConnectionFigure 3-6 3-Wir

Page 18

3.5 CONNECTING MAIN POWERConnect the ac main power connections as shown in Figure 3-8.Warning: Do not connect AC power to your device until you haveco

Page 19 - 2.7 DISASSEMBLY

3.5 CONNECTING MAIN POWER (Continued)Connect the dc main power connections as shown in Figure 3-9..Figure 3-9 Main Power Connections (dc powered unit

Page 20 - SECTION 3. GETTING STARTED

3.6 ANALOG AND RELAY OUTPUT CONNECTIONS (continued)Figure 3-11 Analog Output ConnectionsFigure 3-12 Isolated Analog Output Connections19

Page 23 - Figure 3-4 Panel Cut-Out

PREFACEManual ObjectivesThis manual shows you how to set up and use the Differential RTD Meter.Standard Procedures:* Checking voltage jumpers, or chan

Page 45

NOTES, WARNINGS and CAUTIONSInformation that is especially important to note is identified by these labels:• NOTE• WARNING• CAUTION• IMPORTANTNOTE: pr

Page 51

47Table 10-1 Front-Panel Displays (continued)/DEVMENUDESCRIPTION/T1/T2/Table 10-2 Run Mode Display/DEVDISPLAYDESCRIPTION/T1/T2/RESETRunModeLAT

Page 52

48SECTION 11. SETPOINT CONFIGURATION DISPLAYSTable 11-1 Setpoints Configuration DisplaysSP 1Setpoint 1SETPOINT 1Select from -1999through 9999SETPOINT

Page 53

SECTION 12. SPECIFICATIONSSIGNAL INPUTRTD types: DIN (0.00385) type 2,3, or 4 wireNIST (0.00392) type 2,3, or 4 wireLead Resistance for Specified Acc

Page 54

INPUT POWER INFORMATION:~ AC units 115/230 V~(AC) ±10%, 50/60 Hz7 W max, power consumption (Non-Isolated AnalogOutput)8 W max, power consumption (Isol

Page 55 - Changes the value

ANALOG OUTPUT (if applicable)Signal type: Current or voltageSignal level: Current: 10 V max compliance at 20 mA outputVoltage: 20 mA max for 0-10 V ou

Page 56

ivTable of ContentsSectionPage1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11.1 UN

Page 57 - SECTION 12. SPECIFICATIONS

SIDE VIEWTOP VIEWCASEREAR COVER96,0 (3.78)48,0 (1.89)20,3 (.80)151,4 (5.96)RETAINERFRONT BEZEL45,00 + 0,61/-0,00(1.772 + .024/–.000)92,00 + 0,81/–0

Page 58 - MECHANICAL

MENU ITEM FACTORY PRESET VALUESINPT Input Type: 385.3 (3 wire DIN RTD)DEC.P Decimal Point Position: FFF.FRD.CF Reading Configuration:R.1=F (Fahrenhei

Page 59 - ALARM OUTPUTS (if applicable)

CE APPROVALS INFORMATIONThis product conforms to the EMC directive 89/336/EEC amended by93/68/EEC, and with the European Low Voltage Directive 72/23/E

Page 60 - Figure 12-1 Meter Dimensions

WARRANTY/DISCLAIMEROMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of one (1)year from the

Page 61 - 0-1000 = 4-20 mA dc

M1865/0206 11869ML-96 Rev.BWhere Do I Find Everything I Need for Process Measurement and Control? OMEGA…Of Course!Shop on line at www.omega.comTEMPERA

Page 62 - CE APPROVALS INFORMATION

vSectionPage4.8 SELECTING OUTPUT CONFIGURATION (OT.CF) . . . . . . . . . . . . . .264.8.1 Enabling or Disabling The Analog Output . . . . . . . .

Page 63 - RETURN REQUESTS/INQUIRIES

viList of FiguresFigureFigure 2-1. Front-Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5Figure 2-3.

Page 64 - Shop on line at www.omega.com

1SECTION 1. INTRODUCTION1.1 UNPACKINGRemove the Packing List and verify that all equipment has been received. If there areany questions about the sh