12. ALARM OUTPUT
12.4 Programming Output Mode
4 Programming Mode




5 Programming Flow Chart
<Example> Programming the relay coil phase to Energize, relay output/display to Hold and alarm display to
Hold:
Operation screen
[Check]


[To be ready for programming]


[Selecting relay coil]


[Selecting relay output]


Stored
The parameters are displayed in order
of (1) relay coil phase, (2) relay output
and (3) alarm display.
Relay coil phas
e
: Energize
:
Not energize
Relay output/
display
: Hold : Not hold
Store the parameters into memory.
(Programming change mark is
printed.)
Rela
y
coil
Relay output
and display
Cursor
(1)
(2)
Relay coil
Relay output and display
3 sec. or more
DISP
DISP
°
C
SET
END
%
/
°F
%
/
ENTRY
Ref. 1
Ref. 2
Checking
Reference 1
Stored
Reference 2